Measurements and Instrumentation Part 11
Category –EE Online Test
Telegram-Join Us On Telegram
Attempt Free Measurements and Instrumentation Part 11 Here. Read The Important Electrical MCQ From Below.
1. The main shortcomings of diaphragms are that they are prone to shock vibrations.
2. Diaphragms have the advantages of high accuracy and good dynamic response
3. Selection of material for diaphragms mainly depends upon temperature range and chemical nature of fluid coming in contact with diaphragm during pressure measurement.
Which of the above statements is/are correct? [IES2010]
A. 1,2 and3
B. 2 and 3 only
C. 1 only
D. 1 and 2 only
Answer
[2] If reflection coefficient for voltage be 0.6, the voltage standing wave ratio(VSWR) is [IES2010]
A.0.66
B.4
C.1.5
D.2
Answer
Measurements and Instrumentation Part 11
[3] A resistance strain gage with gage factor (Sf) of 2 is bonded to a steel member, which is subjected to a strain of 1 x 10-6.The original resistance value of this strain gage is 120Ω.The change in resistance due to the applied strain is [IES2010]
B. 240 x 10-6 Ω
C. 240Ω
D. 60 x 10-6 Ω
Answer
[4] Consider the following statements: [IES2010]
1. Crystal can be shown as electrical equivalent circuit similar to an inductor and a capacitor(Tank circuit).
2. Quartz,Rochelle salt,tourmaline.
3. Used in voltage stabilizers.
4. This exhibits the reverse effect of electrostriction.
Which of the above statements are correct?
A. 1,2 and 4 only
B. 1 and 2 only
C. 2 and 4 only
D. 1,2,3 and 4
Answer
Measurements and Instrumentation Part 11
[5] Consider the following units for the measurement of pressure directly: [IES2010]
1. Rolta meter
2. Bourdon tube
3. Planti meter
4. Vanes
Of these, the pressure can be measured by
A. 1 and 2 only
B. 3 and 4 only
C. 2 only
D. 1,2,3 and 4
Answer
[6] The measurement of Hall coefficient of a semiconductor with one type of charge carrier gives the information about [IES2010]
A. Sign of charge carrier
B. Density of charge carrier
C. Both sign and density of charge carrier
D. Mass of the charge carrier
Answer
Measurements and Instrumentation Part 11
[7] A piezoelectric crystal has a thickness of 2.5mm and a voltage sensitivity of 0.05Vm/N. The piezoelectric crystal is subjected to an external pressure of 1.6 x 106N/m2,then the corresponding output voltage is, [IES2010]
A. 200V
B. 3.2 x 109V/m of thickness
C. 0.07 x 10-9V/(m3/New)
D. 200m V
Answer
[8]The two inputs of a CRO are fed with two stationary periodic signals. In the X-Y mode, the screen shows a figure which changes from ellipse to circle and back to ellipse with its major axis changing orientation slowly and repeatedly. The following inference can be made from this. [GATE2009]
[9]The pressure coil of a dynamo meter type wattmeter is [GATE2009]
[10]The measurement system shown in the figure uses three sub systems in
cascade whose gains are specified as G1, G2 and 1/G3. The relative
small errors associated with each respective subsystem G1, G2,G3 are ε1,ε2 and ε3.The error associated with the output is [GATE2009]
Answer
Measurements and Instrumentation Part 11