Electric Machine Design PART 7 ONLINE Multiple Choice Questions

Electric Machine Design PART 7

Electric Machine Design PART 7

Category –EE Online Test

Telegram-Join Us On Telegram

Attempt Free Electric Machine Design PART 7 Here. Read The Important Electrical MCQ From Below.

91. The disadvantage of cylindrical winding is
(A) increased eddy current loss
(B) high copper loss
(C) low mechanical strength
(D) all of the above.

Get Answer

92. For transformer laminations
(A) hot rolled silicon steel is preferred
(B) cold rolled silicon steel is preferred
(C) grain oriented silicon steel is preferred
(D) any of the above steel can be used.

Get Answer

93. The percentage of silicon in the core steel is
(A) 1 to 2 percent
(B) 2 to 3 percent
(C) 4 to 6 percent
(D) 8 to 10 percent.

Get Answer

Electric Machine Design PART 7

94. The stacking factor will be least for
(A) Square core
(B) Cruciform core
(C) Three stepped core
(D) Four stepped core.

Get Answer

95. In static transformers mechanical forces are produced due to
(A) vibrations
(B) gap between laminations
(C) interaction of current flowing in the conductor and leakage flux around it.
(D) none of the above.

Get Answer

96. The thickness of laminations of the core of a power transformer usually
(A) 0.003 to 0.05 mm
(B) 0.03 to 0.05 mm
(C) 0.03 to 0.5 mm
(D) 3 to 5 mm.

Get Answer

97. Transformer action requires a
(A) short circuiting
(B) increasing resistivity
(C) reducing resistivity
(D) all of the above.

Get Answer

Electric Machine Design PART 7

98. In an oil filled transformer, oil is provided for
(A) Cooling
(B) Insulation
(C) Lubricating
(D) Both cooling and insulation
(E) Preventing accumulation of dust.

Get Answer

99. The dimensions of a dc machine primarily depend on
(A) kW output
(B) work done per revolution
(C) exposed surface
(D) none of the above.

Get Answer

Questions 100 to 104 are based on data below:

The various losses of a 60 HD, 220 V 850 rpm dc motor are as follows: – Copper losses 3.2 kW, core losses 0.8 kW, mechanical losses 0.1 kW. Now let us consider another dc machine otherwise similar to this machine but having its linear dimensions 1.5 times.

100. The copper losses of new machine will be
(A) 1.5 x 3.2 kW
(B) (1.5)2 x 3.2 kW
(C) (1.5 )3 x 3.2 kW
(D) 1/(1.5)2 x3.2 kW

Get Answer

Electric Machine Design PART 7

101. The iron losses of new machine will be
(A) (1.5) x 0.8 kW
(B) (1.5)2 x 0.8 kW
(C) (1.5)4 x 0.8 kW
(D) (1.5)5x 0.8 kW

Get Answer

102. The mechanical losses will be
(A) 1.5 x 0.1 kW
(B) (1.5)2 x 0.1 kW
(C) (1.5)3 x 0.1 kW
(D) 1/ (1.5)2 x 0.1 kW

Get Answer

103. The rating of the new machine will be
(A) 1.5 x 60 HP
(B) (1.5)2 x60 HP
(C) (1,5)3 x 60 HP
(D) (1.5)4 x 60 HP.

Get Answer

104. The efficiency of the new machine will be
(A) 88.8%
(B) 91.7%
(C) 94.5%
(D) 96.7%.

Get Answer

Electric Machine Design PART 7

105. The diameter of a 10 SWG wire will be closer to
(A) 0.1 mm
(B) 1mm
(C) 3 mm
(D) 13 mm.

Get Answer

Leave a Comment